Applications created with the Netplex framework all share the
following configuration settings and allow some basic
administration commands. This is only a common minimum - the
applications typically define more than this.



{1:config Configuration}

The Netplex config file has the following layout:

{[
netplex {
  controller { <settings> };    (* only one controller section *)
  service { <settings> };       (* as many service sections as running services *)
  ...
  service { <settings> };
  (* The application can define further types of sections *)
}
]}



{2:controller Configuration: The [controller] section}

This section configures the controller component. The task of the
controller is to start the containers for the workload, and logging.

{[
netplex {
  controller {
    socket_directory = "<path>";
    max_level = "<debuglevel>";
    logging { <settings> };    (* several logging destinations possible *)
    ...
    logging { <settings> };
  };
  ...
}
]}

Settings:
- [socket_directory]: The Netplex framework needs a directory where to
  create Unix domain sockets. These sockets are needed for communication
  between the started containers. If omitted, the directory defaults to
  [/tmp/netplex-<id>] (where the id part is derived from the file location of
  the configuration). It is not allowed that several running Netplex instances
  share these directories, and hence it is strongly recommended to change
  this default. If the path is not absolute, it is made absolute by
  prepending the path of the working directory at the time Netplex
  is started (usually the program start). Note that the paths of
  Unix domain sockets are limited to 107 bytes for historic reasons,
  so the [socket_directory] should not be put too deeply into the
  file hierarchy.
- [max_level]: This can be set to globally limit the log level. Defaults
  to "debug", i.e. no maximum.

Log levels are (same as for syslog):
- emerg
- alert
- crit
- err
- warning
- notice
- info
- debug

Every [logging] section defines a logging destination. Log messages
are written to all destinations that do not filter the messages out.
There are several types of [logging] sections:

{3:logerr Logging to stderr}

This type writes log messages to stderr:

{[
netplex {
  controller {
    logging {
      type = "stderr";                        (* mandatory *)
      format = "<format string>";             (* optional *)
      component = "<name_of_component>";      (* optional *)
      subchannel = "<name_of_subchannel>";    (* optional *)
      max_level = "<max_level>";              (* optional *)
    };
    ...
  };
  ...
}
]}

The settings [format], [component], [subchannel], and [max_level] may also
occur in the other types of logging definitions, and are explained below.

{3:logfile Logging to a file}

This writes the log messages to a single file.

{[
netplex {
  controller {
    logging {
      type = "file";                          (* mandatory *)
      file = "<path>";                        (* mandatory *)
      format = "<format string>";             (* optional *)
      component = "<name_of_component>";      (* optional *)
      subchannel = "<name_of_subchannel>";    (* optional *)
      max_level = "<max_level>";              (* optional *)
    };
    ...
  };
  ...
}
]}

Settings:
- [file]: The file to which the messages are appended. If not existing,
  the file is created. The file path must be absolute.

The settings [format], [component], [subchannel], and [max_level] may also
occur in the other types of logging definitions, and are explained below.

{3:logmfile Logging to multiple files}

This logging definition directs to create several files in a common
directory.

{[
netplex {
  controller {
    logging {
      type = "multi_file";                    (* mandatory *)
      directory = "<path>";                   (* mandatory *)
      format = "<format string>";             (* optional *)
      file { <settings> };
      ...
      file { <settings> };
    };
    ...
  };
  ...
}
]}

The settings in the [file] section:

{[
  file {
    file = "<name>";                        (* mandatory *)
    format = "<format string>";             (* optional *)
    component = "<name_of_component>";      (* optional *)
    subchannel = "<name_of_subchannel>";    (* optional *)
    max_level = "<max_level>";              (* optional *)
  };
]}

Settings:
- [directory]: The absolute path of the directory where to create
  the log files managed by the [file] subsections
- [file]: The name of the file in this directory

The settings [format], [component], [subchannel], and [max_level] may also
occur in the other types of logging definitions, and are explained below.
Note that a [format] setting in the [file] section overrides the
definition in [logging] for the respective file.

{3:logsys Logging to syslog}

The log messages are sent to the syslog device of the system
(Unix only).

{[
netplex {
  controller {
    logging {
      type = "syslog";                        (* mandatory *)
      identifier = "<identifier>";            (* optional *)
      facility = "<facility>";                (* optional *)
      format = "<format string>";             (* optional *)
      component = "<name_of_component>";      (* optional *)
      subchannel = "<name_of_subchannel>";    (* optional *)
      max_level = "<max_level>";              (* optional *)
    };
    ...
  };
  ...
}
]}

Settings:
- [identifier]: A string prefixing each message. Default: empty.
- [facility]: The syslog facility name. Defaults to "default".

Facility names:
- authpriv
- cron
- daemon
- ftp
- kern
- local0 to local7
- lpr
- mail
- news
- syslog
- user
- uucp
- default

{3:logcommon Common settings in [logging]}

{b [format]:} This parameter defines how the log messages look like.
This is a string containing variables in dollar notation ([$name] or 
[${name}]). The following variable specifications are defined:

 - [timestamp]: the time in standard format
 - [timestamp:<format>] the time in custom format where [<format>] is a
   {!Netdate} format string
 - [timestamp:unix]: the time in seconds since the epoch
 - [component]: the name of the component emitting the log message
 - [subchannel]: the name of the subchannel
 - [level]: the log level
 - [message]: the log message

The standard format string is
{[ [${timestamp}] [${component}] [${level}] ${message} ]}


{b [component]:} This parameter filters messages by the component 
emitting the messages. The component name is here the Netplex
service name, i.e. the [name] parameter in the [service] section
(see below). The parameter may be set to the component name, or
to a pattern matching component names. The wildcard [*] can be used
in the pattern.

Default: [*]

{b [subchannel]:} Netplex allows it to have several log channels per
component. There is normally only the main log channel, but components
can define additional channels. For example, a web server may have
a separate log channel for access logging. This parameter filters
messages by the subchannel identifier. Again it is possible to use
the wildcard [*].

The main log channel has the empty string as subchannel identifier,
hence [subchannel=""] restricts the messages to the main channel.

Default: [*]

{b [max_level]:} Restricts the log level of the printed messages.
See above for possible levels.

{3 Examples for logging definitions}

1. Write everything to stderr:

{[
  logging { type="stderr" }
]}

2. Write a separate file for each log level:

{[
  logging {
    type = "multi_file";
    directory = "/var/log/myapp";
    file {
      max_level = "debug";
      file = "all_debug.log";
    };
    file {
      max_level = "info";
      file = "all_info.log";
    };
    ... (* and so on ... *)
    file {
      max_level = "emerg";
      file = "all_emerg.log";
    };
  }
]}

3. Write errors to syslog, but write access logs to a file:

{[
  logging {
    type = "syslog";
    max_level = "err";
    subchannel = "";    (* i.e. only the main log channel goes here *)
  };
  logging {
    type = "file";
    file = "/var/log/myapp/access.log";
    subchannel = "access";
  }
]}



{2:service Configuration: The [service] section}

Each service section instructs Netplex to start containers for the
service. If a service type is only defined by the application, but
does not appear in the config file, no containers will be started!

A service section looks like:

{[
netplex {
  service {
    name = "<name>";                 (* mandatory *)
    user = "<user>";                 (* optional *)
    group = "<group>";               (* optional *)
    startup_timeout = <float>;       (* optional *)
    conn_limit = <int>;              (* optional *)
    gc_when_idle = <bool>;           (* optional *)
    protocol { <settings> };         (* at least one *)
    ...
    protocol { <settings> };         (* at least one *)
    processor { <settings> };        (* mandatory *)
    workload_manager { <settings> }; (* mandatory *)
  };
  ...
}
]}

The [name] of the service is a freely chosen identifier. It is used
to reference the service, e.g. in log messages.

Each [protocol] section defines a set of sockets with common
properties. The idea here is that a service may define several
protocols for accessing it, e.g. an HTTP-based protocol and an
RPC-based protocol. For each protocol there can then be several
sockets.

The [processor] section is the connection to the application
which must have defined the type of processor that is referenced
here. The task of the processor is to accept incoming connections
and to process them.

The [workload_manager] section defines how many containers (i.e.
subprocesses or threads) are created for serving incoming connections.

Settings:
- [user]: If the program is started as user [root], it is possible to
  change the user for subprocesses. This parameter is the user name
  for all subprocesses created for this service. This is only possible
  when Netplex is running in the multi-processing mode, not in the
  multi-threading mode. Default: do not change the user.
- [group]: Same for the group
- [startup_timeout]: If a subprocess does not start up within this
  period of time, it is considered as dysfunctional, and killed again.
  This misbehavior usually occurs because the initialization function
  of the subprocess hangs.
  This setting has only an effect in multi-processing mode.
  Default: 60 seconds. A negative value turns this feature off.
- [conn_limit]: If set, a container is automatically shut down if
  it has processed this number of connections. This is sometimes
  useful if there is a memory leak in the container, or memory is
  not reclaimed quickly enough. Of course, one can only fight memory
  problems in multi-processing mode this way. Default: no limit.
- [gc_when_idle]: If [true], the Ocaml garbage collector is run
  if a container is idle for one second.


{3:protocol The [protocol] subsection}

It looks like:

{[
netplex {
  service {
    protocol {
      name = "<protoname>";      (* mandatory *)
      lstn_backlog = <int>;      (* optional *)
      lstn_reuseaddr = <bool>;   (* optional *)
      so_keepalive = <bool>;     (* optional *)
      tcp_nodelay = <bool>;      (* optional *)
      local_chmod = "...";       (* optional *)
      local_chown = "...";       (* optional *)
      address { <settings> };    (* at least one *)
      ...
      address { <settings> };    (* at least one *)
    };
    ...
  };
  ...
}
]}

Settings:
- [name]: The name of the protocol. This is an arbitrary identifier.
  The name is passed to some hook functions.
- [lstn_backlog]: The value of the backlog parameter of the [listen]
  system call. When a TCP connection is being accepted, the kernel does
  this first on its own, and passes the accepted connection to the application
  at the next opportunity (i.e. the [accept] system call). Because of this
  connections can queue up in the kernel, i.e. connections that are accepted
  but not yet passed to the application. This parameter is the maximum
  length of this queue. Note that there is usually also a kernel-defined
  maximum (e.g. 128 on Linux). If you get spurious [EAGAIN] errors
  on the client side this might be an indication to increase this parameter.
- [lstn_reuseaddr]: Whether to allow immediate reuse of socket addresses.
  Defaults to [true].
- [so_keepalive]: Whether to enable the TCP keep-alive feature which is
  useful to detect unresponsive TCP connections (after a very long timeout
  only, though). Defaults to [false].
- [tcp_nodelay]: Whether to disable the Nagle algorithm for TCP. Normally,
  TCP packets are minimally delayed before they are sent to the network
  in the hope that the application makes more data available that could be
  put into
  the same packet. Especially on local networks it is often not important
  how many packets are really sent out, and by enabling this option
  latencies can be, sometimes drastically, reduced. Defaults to [false].
- [local_chmod]: For Unix Domain sockets, this sets the file permission
  bits. E.g. [local_chmod = "0o700"]
- [local_chown]: For Unix Domain sockets, this sets the owner and group
  of the socket. E.g. [local_chown = "owner:group"]. Both settings can also
  be given numerically.

Specifying socket addresses:
- [address { type="internet"; bind="<ip>:<port>" }]: An IPv4 or IPv6
  socket. The IP address can also given as host name which is looked up
  at Netplex startup. Use [0.0.0.0] as the IPv4 catch-all address. IPv6
  addresses must be put into brackets. Use [[:0]] as the IPv6 catch-all
  address.
- [address { type="local"; path="<path>" }]: 
  This is a OS-dependent default IPC mechanism for local
  connections. On Unix, [local] means Unix Domain sockets. On Win32,
  [local] means the [w32_pipe_file] mechanism (see below). In [path], the name
  of the Unix Domain socket or the file with the pipe name must be
  specified.
- [address { type="unixdomain"; path="<path>" }]: 
  Unix domain sockets. In [path] give the path.
- [address { type="socket_file"; path="<path>" }]: 
  An emulation of Unix Domain sockets: A server socket
  bound to [127.0.0.1] and an anonymous port is used instead. The
  port number is written to a file. The file must be given as [path].
- [address { type="w32_pipe"; path="<path>" }]: 
  Win32 named pipes. The name of the pipe is given
  as [path]. This must be a name of the form "\\.\pipe\<name>".
  The pipe server is configured so that only clients on the same
  system can connect to it.
- [address { type="w32_pipe_file"; path="<path>" }]:
  An emulation of Unix Domain sockets: A named
  pipe with an unpredictable random name is created instead. The
  name of this pipe is written to the file given by [path].
- [address { type="container" }]: 
  This special address causes that a separate [local]
  socket is created for each started container. The name of the
  socket file is automatically chosen. The names of the socket
  files can be queried with {!Netplex_cenv.lookup_container_sockets}.
  This type of socket is useful to control the load sent to each
  container directly.

{3:processor The [processor] subsection}

This section depends on the Netplex processor connected with it.
At minimum, this section has only a parameter [type] that is the
name of a defined Netplex processor type:

{[
netplex {
  service {
    processor {
      type = "<type>";
      ... (* rest depends on the type *)
    };
    ...
  };
  ...
}
]}

There are a number of processor types coming with Ocamlnet:

- {!Rpc_netplex}: RPC servers
- {!Netcgi_plex}: Web connectors (e.g. FastCGI)
- {!Nethttpd_plex}: Web servers

See these modules for how to configure the processors defined by them.



{2:workload Configuration: The [workload_manager] section}

The workload manager determines how many containers (processes or
threads) are running for each service.


{3:constworkload The constant workload manager}

The constant workload manager starts a fixed number of containers.
If containers are shut down or crash, new containers are automatically
launched to replace the missing ones.

The config section looks like:

{[
netplex {
  service {
    workload_manager {
      type = "constant";
      threads = <n>;
    }
  }
}
]}

Note that the parameter [threads] is also interpreted in
multi-processing mode (as number of processes).

Since Ocamlnet-3.5, there are two optional settings:

- [max_jobs_per_thread]: This number can be set to the maximum number of
  connections a thread or process can be assigned simultaneously. By default
  there is no limit.
- [greedy_accepts]: This is a boolean (values [true] or [false]). If
  this mode is turned on, processes accept new connections more aggressively.
  This may improve the performance for very high connect rates (e.g.
  for more than 1000 new connections per second). The downside is that
  the load is assigned to processes in a less balanced way.

{3:dynworkload The dynamic workload manager}

The dynamic workload manager starts as many containers as needed to
handle the current load. Initially, a certain minimum number is started.
If it turns out that too many containers become busy, more containers
are started until a maximum is reached. If too many containers become
idle containers are shut down.

{[
netplex {
  service {
    workload_manager {
      type = "dynamic";
      max_jobs_per_thread = <n>;            (* optional, default: 1 *)
      recommended_jobs_per_thread = <n>;    (* optional *)
      min_free_jobs_capacity = <n>;         (* mandatory *)
      max_free_jobs_capacity = <n>;         (* mandatory *)
      max_threads = <n>;                    (* mandatory *)
    }
  }
}
]}

A thread is here a container, even in multi-processing mode. A job
is a TCP connection processed by a container. It is possible that
a container can process several jobs at the same time (but only a
few service types support this, e.g. RPC servers), and the whole
calculation is based on the job capacity, i.e. the number of jobs
all containers can execute in parallel.

The workload manager adjusts the number of containers so that there
is always free capacity for [min_free_jobs_capacity], but the free
capacity does not exceed [max_free_jobs_capacity]. Also, the number
of containers is capped by [max_threads].

As mentioned, in most cases a container can only run one job at a
time (this is meant with [max_jobs_per_thread=1]). Then
[min_free_jobs_capacity] is just the minimum number of idle
containers, and [max_free_jobs_capacity] the maximum number.

If more than one job can be executed, set [max_jobs_per_thread] to
a value bigger than one. The workload manager assigns the components
then up to this number of TCP connections to process. A component
is filled up with jobs until it is full before jobs are assigned
to the next container.

The latter behavior can be modified by [recommended_jobs_per_thread].
This must be a number less than or equal to [max_jobs_per_thread],
and it means that the containers normally only get the recommended
number of jobs until they are "full", and only for very high workloads
this scheme is left, and even more jobs are assigned to the containers
until the maximum is reached. A common configuration is to set
[recommended_jobs_per_thread=1], so that each container gets first
only up to one job, and only if the maximum number of containers are
running, additional jobs can be assigned.

There are also a few rarely used options for the dynamic workload
manager:

- [greedy_accepts]: This is a boolean (values [true] or [false]). If
  this mode is turned on, processes accept new connections more aggressively.
  This may improve the performance for very high connect rates (e.g.
  for more than 1000 new connections per second). The downside is that
  the load is assigned to processes in a less balanced way. Note that
  this mode only works for asynchronously implemented processors.
  (Since Ocamlnet-3.5.)


{1:admin The [netplex-admin] command}

Ocamlnet installs a little utility command [netplex-admin] that can
be used to administer a {b running} Netplex program.

{[
$ netplex-admin -help
Usage: netplex-admin [ options ] [ admin_cmd arg ... ]
  -sockdir <dir>  Set the socket directory of the Netplex to administer
  -conf <file>  Get the socket directory from this config file
  -list   List available Netplex services
  -containers   List available Netplex services with container details
  -enable <name>  Enable service <name>
  -disable <name>  Disable service <name>
  -restart <name>  Restart service <name>
  -restart-all   Restart all services
  -shutdown   Shutdown the whole Netplex
  -reopen-logfiles   Reopen logfiles (if possible)
  -unlink   Unlink persistent kernel objects
  -receiver <pat>  Restrict receivers of admin messages to services matching <pat>
]}

The utility talks to the running program, and needs the socket directory
for this. Either specify it directly with the [-sockdir] argument, or
indirectly via the config file ([-conf]).

The [-list] and [-containers] switches allow it to get some introspection
into the running conglomerate of processes or threads. For [-list]
the services and the socket addresses are printed. For [-containers]
even more details are emitted, including the process IDs.

The [-enable], [-disable], and [-restart] commands allow it to
manage the set of running services. A service can be disabled, which
means that all containers are shut down. Note that this does not mean
that incoming TCP connections are rejected. They are just not processed.
If enabled again, the containers are started again for the service,
and the processing of TCP connections is resumed (including the
connections that were accepted during the downtime). Disabling a
service is useful for temporarily stopping the service, e.g.
because it would interfer with other admin tasks.

A restart means to disable and re-enable the service. It may be
useful for cleanly reinitializing a service.

With [-restart-all] even all services are restarted that are running
within the Netplex framework.

A [-shutdown] starts the shutdown sequence. The shutdown is announced
to all containers, and in a second step, the containers are terminated.
Finally, the master process is also stopped.

The command [-reopen-logfiles] is meaningful for all file-based
logging definitions. The current set of files is closed, and reopened
again. This is useful as post-action after log file rotation (see below).

[-unlink]: see below.

[netplex-admin] can also be used to send so-called admin messages to
the containers. These messages have a name and optionally arguments:

{[
$ netplex-admin ... name arg1 arg2 ...
]}

Generally, the possible admin commands must be defined by the Netplex
processors. A few commands are defined by default, though:

- [netplex.threadlist]: Outputs information about threads and processes
  to the log file
- [netplex.logger.set_max_level <level>]: Changes the maximum log level
  to the level passed in the argument
- [netplex.debug.enable <module>]: Enables debug logging (as controlled
  by {!Netlog.Debug} for the module named in the argument. 
- [netplex.debug.disable <module>]: Disables debug logging (as controlled
  by {!Netlog.Debug} for the module named in the argument. 
- [netplex.fd_table]: prints the file descriptor tracking table to
  the log file
- [netplex.connections]: prints information about current TCP
  connections to the log file
- [netplex.mem.major]: triggers a major GC run
- [netplex.mem.compact]: triggers a GC compaction
- [netplex.mem.pools]: output information about Ocamlnet pools to
  the log file
- [netplex.mem.stats]: output information about the memory managed by
  the Ocaml runtime to the log file



{1:logrotate How to configure log file rotation}

[logrotate] is a common utility to perform log file rotation. It can
be easily used together with Netplex. The essential point is to
run [netplex-admin -reopen-logfiles] as post action to the rotation.
This stanza is an example how to configure the rotation in a
[logrotate] config file:

{[
/var/log/myapp/file.log
{
	weekly
        rotate 10
        missingok
        sharedscripts
        postrotate
                /some/path/bin/netplex-admin \
                        -sockdir /var/lib/myapp/sockdir \
                        -reopen-logfiles
        endscript
}
]}


{1:unlink Deleting persistent kernel objects}

For some functionality, Netplex programs allocate persistent kernel
objects:

 - POSIX shared memory
 - POSIX named semaphores
 - Temporary regular files

These objects are effectively only used temporarily, but the available
system interfaces only allow it to allocate them in a kernel-persisting
manner. This means that the objects are not automatically released if
the program ends, like most other system resources, but that they remain
in memory after termination. If they were just left there behind, they
would consume memory forever.

Of course, most Netplex programs are carefully written, and delete these
objects if the program ends in a regular way. However, after a crash
the programs normally don't have a chance to delete the objects. In order
to allow administrative removal, many Netplex programs write the names
of these objects into a special file [netplex.pmanage] residing in the
socket directory. The [netplex-admin] command has a special mode in
order to perform the deletion:

{[
netplex-admin -sockdir /path/to/sockdir -unlink
]}

Some operating systems have actually means for adminstering the
kind of objects managed this way, but some have not. For example,
Linux reflects the objects as normal files in the [/dev/shm]
directory. As a counter example, there is no administration possibility
in OS X.

(For programmers: The Netplex interface to access [netplex.pmanage]
is {!Netplex_cenv.pmanage}.)